loading

Dubhe is a leading high-tech enterprise has advanced wastewater treatment systems and environmental protection equipment.

Microfiltration Membrane Membrane System Wholesale - DUBHE 1
Microfiltration Membrane Membrane System Wholesale - DUBHE 2
Microfiltration Membrane Membrane System Wholesale - DUBHE 1
Microfiltration Membrane Membrane System Wholesale - DUBHE 2

Microfiltration Membrane Membrane System Wholesale - DUBHE

Inquiry

Product details of the microfiltration membrane


Quick Overview

The whole production process of DUBHE microfiltration membrane is under the strict supervision of professionals. This product is defectless and stringently tested on different quality parameters by our team of experts. The equipment of advanced development guarantees the production of a microfiltration membrane.


Product Information

Want to know more about product information? We will provide you with detailed pictures and detailed content of microfiltration membrane in the following section for your reference.

Membrane Element Specifications
Membrane Element Model 50150
Membrane configuration Flat sheet
Application Filtration of activated sludge
Filtration method Suction filtration
Nominal pore diameter (um) 0.08
Effective membrane area (㎡) 1.4
Dimensions (mm) Total width (mm) 515
Total height (mm) 1608
Thickness (mm) 13.5
Main material Membrane (mm) PVDF and PET non-woven fiber
Supporting panel (mm) ABS resin

Monolithic Membrane Element Parameters 

C

Technical Parameters

MBR
  DEM140-50S DEM140-100S DEM140-200W DEM140-200D DEM140-400W
Design flow rate (m³/d) 8-53 15-105 30-210 30-210 60-420
Number of membrane elements (pcs) 50 100 200 200 400
Total membrane area (㎡) 70 140 280 280 560
Membrane Module Size width (mm) 810 810 840 810 840
length (mm) 950 1620 3260 1620 3260
height (mm) 2100 2100 2100 4160 4160
Weight (kg) Dry 400 695 11430 1365 2690
Materials Frameworks SUS316 SUS316 SUS316 SUS316 SUS316
Produced water collection master tank SUS316 polypropylene
Aeration pipe
Membrane Element Retaining Gasket EPDM rubber
Connecting flange Produced water collection master tank ANSI 1 ½ inch ANSI 2 inch ANSI 3 inch ANSI 2 inch ANSI 3 inch
Aeration pipe ANSI 1 ¼ inch ANSI 1 ½ inch ANSI 2 inch ANSI 1 ½ inch ANSI 2 inch
Operating range Temp 5-40℃
FluidsPH 5-10
MLSS not higher than18000mg/l
Transmembrane pressure not higher than 20KPa(200mbar)

Application Areas

•Large-scale wastewater projects

•Organic wastewater treatment;

•Old sewage plant process improvement;

•Surface water purification treatment;

•Reverse osmosis system influent pre-treatment;

•Restaurant or landscape wastewater treatment and reuse;

•Car wash plant ship sewage recycling and reuse;

•Various types of beverage factories, distilleries, food factories, livestock factories, slaughterhouses, dyeing and finishing plants, leather factories, pulp mills;

•Wastewater treatment for pharmaceutical factories and high concentration organic treatment plants;

•Large municipal wastewater treatment and reuse, community living water reuse, department stores, office building water reuse, sewage water reuse

A-2 (23)

How to install DEM140-Flat film

Microfiltration Membrane Membrane System Wholesale - DUBHE 5
Installation Preparation
• Confirm the handling plan for placing the membrane modules into the bioreactor, including transport routes.• Prepare equipment for unloading membrane modules from the truck (e.g., forklift, crane, trailer).• Ensure all construction work inside the reactor tank is completed and the area is cleaned. Remove any large debris (e.g., concrete blocks, metal chips, residual materials) that may remain in the tank.
B-3 (12)
Membrane Element Disassembly
When unloading membrane elements, use appropriate equipment (forklift, crane, or trailer) and follow the specified lifting methods according to the packaging type:• During shipping, the membrane element section and the aeration unit are bundled separately.• When lifting DEM flat-sheet ultrafiltration membrane elements, fully secure hooks to the lifting rings and maintain a horizontal lift. Avoid damaging the membrane's flow guide tubes and aeration pipes, and ensure operational safety throughout the process.
B-2 (14)
Technology Overview
DEM-MBR membrane wastewater treatment technology is an advanced system that integrates membrane separation with biochemical treatment. By retaining activated sludge and macromolecular organics in the bioreactor using DEM membrane separation equipment, the process eliminates the need for secondary sedimentation tanks. This significantly increases activated sludge concentration, allows independent control of hydraulic retention time (HRT) and sludge retention time (SRT), and enables continuous degradation of refractory organic matter within the reactor.

Precautions for use

Unpacking and Installation

● When lifting the membrane module, the hook or chain should be lifted smoothly to prevent the membrane module from shaking. It is strictly prohibited for any personnel to be located under the membrane module.

● When lifting the membrane module shell, use a hook or chain that matches the weight of the membrane module.

● When installing the membrane module, scaffolding should be prepared. Climbing on the shell is absolutely not allowed. Use the necessary protective equipment to ensure the safety of construction personnel.

● In the storage, transportation and use of membrane modules, you need to take the necessary measures to prevent damage to the membrane components, such as prohibited to place heavy objects on top of the membrane modules, as well as to prevent the membrane components and other items collision.

● Avoid placing the membrane module for a long period of time in a temperature environment of 40℃ or higher or in a place under direct sunlight. In particular, the ABS support plate can be damaged by direct sunlight or ultraviolet rays.

● During the whole process from installation to operation, it is strictly prohibited to contact the membrane module with sparks generated by welding, fusing, shearing or grinding.

● Prevent the membrane module from freezing.

● Avoid applying pressure at the water production end.

● In order to protect the membrane and prevent clogging, use a screen of 3mm or less to pre-treat the raw water for the membrane bioreactor.

Operation and Maintenance

● Do not drink the permeate water.

● When discharging or recycling the treated water, analyze the treated water according to the purpose of use and make sure that it meets the requirements for use.

● Hydrogen fluoride (HF) gas occurs when the membrane element is burned after use. When the membrane element is discarded, it must be disposed of by a professionally qualified disposal company.

● Open the air vent valve before adding fresh water to the reaction tank to exhaust the air inside the membrane element. Close the air vent valve after feeding water.

● It is recommended that surface water not be used in place of fresh water for operation, as surface water may cause membrane clogging if it contains large amounts of iron, manganese, calcium, and silica.

● Do not perform excessive clear water testing, as clear water operation may result in membrane clogging.

● Keep the membrane moist after water operation. Drying of the membrane may result in a decrease in water permeability.

● Do not filter without proper aeration, as this may result in clogging of the membrane surface.

● Chemicals, drugs, oils, or other substances that adversely affect activated sludge must not be added to the reaction tank.

● The ABS support plate will be chemically cracked when it comes in contact with some organic solvents, such as alcohol, oil or synthetic detergents. Therefore, contact of the ABS support plate with these substances should be avoided.

● Even within the operating conditions of the membrane module, try to avoid sudden changes in parameters such as temperature, pH, and differential membrane pressure.

● Regularly inspect and replace parts that need to be renewed.

● When removing the membrane module for maintenance, it is necessary to keep the membrane in a moist state at all times. Drying of the membrane may result in a decrease in water permeability.

● When stopping the filtration operation, stop aeration flushing of the membrane. However, it is not necessary to stop aeration during the normal intermittent operation phase of membrane filtration.

Chemical Cleaning of Membrane Elements

● The chemicals used for cleaning may contain substances that may cause harm if they come into contact with the human body. When using chemicals, be sure to wear protective equipment such as eyeglasses and gloves with extreme caution. Be sure to check the contents of the MSDS.

● If the chemical comes into contact with skin or clothing, rinse immediately with plenty of water.

● If the chemical gets into your eyes, immediately flush with plenty of water and seek medical attention.

● When performing chemical cleaning, stop the cleaning operation as soon as you notice any abnormalities.

● Do not use a dosing pump to inject chemicals directly into the membrane element, as this may cause damage to the membrane element due to internal pressure rise. The agent must be injected by gravity or at a pressure of 10kPa or less.

● When using a dosing pump, make sure that the membrane module is completely submerged in water and that the distance between the liquid level and the top of the membrane module is more than 500mm.

● Chemicals should be kept in a cool place, avoiding direct sunlight.

● In order to avoid corrosion, please choose storage tanks made of appropriate materials to hold the chemicals according to the nature of different chemicals.

● Sodium hypochlorite should not be mixed with heavy metals or acids. Please pay special attention to the fact that when it is mixed with acid, toxic chlorine gas will be produced.

● Do not mix oxalic or citric acid with sodium hypochlorite. They produce toxic chlorine gas when mixed.

● Please stop aeration flushing during chemical cleaning, otherwise the membrane element may be damaged.

Product scenario

B-1 (10)
B-1 (10)
B-2 (14)
B-2 (14)
B-3 (12)
B-3 (12)


Company Advantages

Shanghai Dubhe Environmental Protection Technology Co.,Ltd is an integrated company in the industry. We are engaged in the production, processing and sales of Wastewater Treatment Equipment,Reverse Osmosis Membrane Element,Air aerator,Biofilter media,Membrane system,Solid Liquid separation Machine,Pump,Air Blower,industrial mixer. Our company will continue to adhere to the business concept of 'customer service, customer satisfaction', and follow the spirit of 'strive for better, pursue excellence'. With the strong technical strength and serious attitude, we will create a first-class brand and build a good corporate image, striving to be a leading company in the industry. Dubhe has a professional team dedicated to product research and development. This ensures the continuous improvement of product quality. Dubhe always adheres to the service concept to meet customers' needs. We are committed to providing customers with one-stop solutions that are timely, efficient and economical.
We can provide you with high-quality products and look forward to your cooperation with us.

Contact us
we welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.

+86-18019736003

DUBHE Co.Ltd. is a professional service in the sewage treatment market system equipment suppliers, engaged in various types of aeration, membrane, pump, blower, sludge dewatering machine, biological filler and other environmental protection equipment design and development, production and sales and international trade as one of the high-tech enterprises.
CONTACT US
Contact Person: Amber
Phone: +86-18019736003
WhatsApp: +86-18019736003
Contact Person: Susie
Phone: +86-17501641229
WhatsApp: +86-17501641229
Address: Room 428. No.255 Xinjinqiao Road Pudong New Area Shanghai China
Customer service
detect